Indesit K6G11S(W)/I Instrukcja Obsługi Strona 15

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 24
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 14
15
Turn the tap to minimum;
Remove the knob and adjust the regulation screw, which
is positioned in or next to the tap pin, until the flame is
small but steady.
N.B.: In the case of liquid gas, the regulation screw
must be screwed in all the way.
Check that the flame does not go out when you turn the
tap quickly from high to low.
d) Regulating the primary air of the burners: The primary air
of the burners does not need to be regulated.
Important
Burner and Nozzle Characteristics
Table 1 Liquid Gas Natural Gas
Burner Diamet-
er
(mm)
Thermal Power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nominal Reduced (mm) (mm) *** ** (mm)
Fast
(Large)(R)
100 3.00 0.7 41 86 218 214 116 286
Semi Fast
(Medium)(S)
75 1.90 0.4 30 70 138 136 106 181
Auxiliary
(Small)(A)
55 1.00 0.4 30 50 73 71 79 95
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
* At 15°C and 1013 mbar- dry gas
** Propane P.C.S. = 50,37 MJ/Kg
*** Butane P.C.S. = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m
3
S
S
R
A
K6G11S/I
On completion of this operation, replace the old rating sticker
with one indicating the new type of gas used. This sticker is
available from our Service Centres.
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, an appropriate pressure
regulator must be installed on the inlet pipe (in compliance
with current National Regulations relative to “regulators for
piped gas”).