GB
19
Burner and nozzle specifications
* At 15°C and 1013 mbar - dry gas
Propane P.C.S. = 50.37 MJ/Kg
Butane P.C.S. = 49.47 MJ/Kg
Natural P.C.S. = 37.78 MJ/m3
Table 1 Liquid gas Natural gas
BURNER
Diameter
(mm)
Thermal power
kW (H.s.*)
By-pass
1/100
(mm)
Injector
1/100
(mm)
Flow *
g/h
Injector
1/100
(mm)
Flow*
l/h
Nomin. Reduc. G30 G31 G20
D. Triple Ring 130 3.25 1.3 57 91 236 232 124 309
A. Auxiliary 55 1.00 0.4 30 50 73 71 71 95
I. Double flame DC DR (internal) 30 0.90 0.4 30 44 65 64 70 86
I. Double Flame DC DR (external) 130 4.10 1.3 57 70 298 293 110 390
Supply pressure
Nominal
Minimum
Maximum
28-30
20
35
37
25
45
20
17
25
! The hob can only be installed above built-in ovens
with a cooling ventilation system.
PMG 41 DCDR ...PMG 41 DCDR ...
PMG 41 DCDR ...PMG 41 DCDR ...
PMG 41 DCDR ...
PMG 42 ...PMG 42 ...
PMG 42 ...PMG 42 ...
PMG 42 ...
II
II
I
DD
DD
D
AA
AA
A