5
GB
5. Turn the knob from the MAX position to the MIN
position quickly or open and shut the oven door,
making sure that the burner is not extinguished.
TECHNICAL DATA
Oven Dimensions
HxWxD
31x43,5x43,5 cm
Volume
58 l
Useful
measurements
relating to the
oven compartment
width 46 cm
depth 42 cm
height 8,5 cm
Voltage and
frequency
see data plate
Burners
may be adapted for use with any
type of gas shown on the data
plate.
EC Directives 2006/95/EC dated
12/12/06 (Low Voltage) and
subsequent amendments -
04/108/EC dated 15/12/04
(Electromagnetic Compatibility)
and subsequent amendments -
2009/142/EC dated 30/11/09 (Gas)
and subsequent amendments -
90/68/EEC dated 22/07/93 and
subsequent amendments. -
2002/96/EC.
1275/2008(Stand-by/Off-mode)
Table of burner and nozzle specifications
WARNING! The glass lid canWARNING! The glass lid can
WARNING! The glass lid canWARNING! The glass lid can
WARNING! The glass lid can
break in if it is heated up.break in if it is heated up.
break in if it is heated up.break in if it is heated up.
break in if it is heated up.
Turn off all the burners andTurn off all the burners and
Turn off all the burners andTurn off all the burners and
Turn off all the burners and
the electric plates beforethe electric plates before
the electric plates beforethe electric plates before
the electric plates before
closing the lid. *Applies to theclosing the lid. *Applies to the
closing the lid. *Applies to theclosing the lid. *Applies to the
closing the lid. *Applies to the
models with glass cover only.models with glass cover only.
models with glass cover only.models with glass cover only.
models with glass cover only.
Table 1 Liquid Gas Natural Gas
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
By Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
Nozzle
1/100
Flow*
l/h
Burner
Nominal Reduced (mm) (mm) *** ** (mm) (mm)
Fast
(Large)(R)
100 3.00 0.7 41 86 218 214 116 286 143 286
Semi Fast
(Medium)(S)
75 1.90 0.4 30 70 138 136 106 181 118 181
Auxiliary
(Small)(A)
55 1.00 0.4 30 50 73 71 79 95 80 95
Oven - 2.60 1.0 52 78 189 186 119 248 132 248
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
13
6,5
18
* At 15°C 1013 mbar-dry gas *** Butane P.C.S. = 49,47 MJ/Kg
** Pro
ane P.C.S. = 50,37 MJ/K
Natural P.C.S. = 37,78 MJ/m³
S
S
R
A
KN6G210/UA
KN6G21/UA
Komentarze do niniejszej Instrukcji