GB
7
appliance, which is indicated by the data plate.
on the data plate.
If the socket is incompatible with the plug, ask an
authorised technician to replace it. Do not use extension
cords or multiple sockets.
! Once the appliance has been installed, the power supply
cable and the electrical socket must be easily accessible.
! The cable must not be bent or compressed.
! The cable must be checked regularly and replaced by
authorised technicians only.
! The manufacturer declines any liability should these
safety measures not be observed.
IF THE FITTED PLUG IS REMOVED
below to a three pin plug of not less than 13 amp capacity.
fuse which is approved to B.S. 1362.
Important: the wires in the mains lead are coloured in
accordance with the following code:
Green & Yellow - Earth
Blue - Neutral
Brown - Live
The power supply cable must be type H05VV-F
Yellow to
Earth
Brown
to Live
Blue to
Neutral
Cord
Clamp
3 Amp
Fuse
As the colours of the wires in the mains lead may not
correspond with the coloured markings identifying the
terminals in your plug, proceed as follows:
Connect the Green & Yellow wire to terminal marked “E”
or or coloured Green or Green & Yellow.
Connect the Brown wire to the terminal marked “L” or
coloured Red.
Connect the Blue wire to the terminal marked “N” or
coloured Black.
IF A MOULDED PLUG IS FITTED
In the event of replacing a fuse in the plug supplied an ASTA
NOTE:
In the event of losing the fuse cover the plug must not be used
new fuse cover can be obtained from your local Electricity Board.
The colour of the correct replacement fuse cover is that of the
coloured marks or inserts in the base of the plug.
Make sure that the cable does not become trapped when
pushing the cooker into position.
Replacing the cable
Use a rubber cable of the type H05VV-F with a cross section
of 3 x 1.5 mm². The yellow-green earth wire must be 2 ÷ 3
cm longer than the other wires.
Gas connection
Connection to the gas network or to the gas cylinder may be
with current national legislation and after making sure that the
appliance is suited to the type of gas with which it will be supplied
(see the rating sticker on the cover: if this is not the case see
below). When using liquid gas from a cylinder, install a pressure
regulator which complies with current national regulations.
! Make sure that the gas supply pressure is consistent with the
(see below). This will ensure the safe operation and durability of
Make sure that the hose complies with current national
legislation. The internal diameter of the hose must measure: 8
mm for a liquid gas supply;13 mm for a methane gas supply.
Once the connection has been performed, make sure that
the hose:
temperatures of over 50°C.
is not kinked or bent.
or moving parts and that it is not compressed.
condition may be checked.
using clamps which comply with current regulations.
!
must be installed according to the conditions listed for class
2 - subclass 1 appliances (installed between two cupboards),
a threaded attachment
Make sure that the hose and gaskets comply with current
national legislation. To begin using the hose, remove the
hose holder on the appliance (the gas supply inlet on the
! Perform the connection in such a way that the hose length
does not exceed a maximum of 2 metres, making sure that
the hose is not compressed and does not come into contact
with moving parts.
Checking the connection for leaks
When the installation process is complete, check the hose
Komentarze do niniejszej Instrukcji